About the intelligent parking lot system ground sense coil installation requirements
2022-07-03 00:00:00
ground sense coil environment have certain requirements for installation, we should pay attention to when installing the following:
1, within the scope of around 50 cm can’t have a lot of metal, such as manhole covers, rain ditch cover plate, etc.
2, around 1 m range cannot be more than 220 v power supply circuit.
3, making multiple coil, the distance between the coil and the coil is greater than 2 m, otherwise it will interfere with each other.
in addition to pay attention to the installation environment, slot cutting should pay attention to the following:
1, parking lot, general sense coil size is about 0.8 meters wide, 2 meters long, the
2, the depth of the slot for 3-5 cm, coil slot width is 0.5 cm, the width of the coil wire slot to 1 cm, depth and width should be uniform, should try to avoid the deep and shallow, wide and narrow.
3, cutting groove is sundry, especially not with hard objects.
4, ground sense coil wire slot to cut to the scope of safety island, avoid lead exposed on the road.
do a good job in these two steps, then we can get the wiring, about wiring need to pay attention to place more, we explain for you next time.