Ground sense coil embedding method and details
2022-07-01 00:00:00
when we planned embedding location, good cutting slot, shall timely bury ground sense coil, it can avoid some debris fell into the trough.Winding embedding procedure is as follows:
1. In order to prevent trough some hard edges cut wire, can on line before the first online slot laid a 0.5 cm thick layer of sand;
2. The choice of ground sense coil requirement: should choose the skin of wear-resisting, high temperature resistant, can waterproof soft copper wire, diameter greater than or equal to 0.5 mm&sup 2;;
3. Coil to clockwise laid, number of turns is in commonly 4 to 6 turns, laying copper wire to the appropriate relaxation, put to be careful, don’t break the skin, placed a circle, and the groove bottom pressure;
4. Copper wire after the shop is good, want to leave a good lead, usually on the safety island end edge line, set aside the thread length is in 1.5 meters or so;
5. Compaction and coil lead wire, 0.5 cm thick sand on the shop, it can prevent the coil skins by high temperature melting;
6. With thin concrete pouring trough, compaction, flush with the road;(http://www.nthuanli.cn/)